c12s-kubespray/roles/network_plugin/cilium/defaults/main.yml
biqiang Wu c681435432
Add switch cilium_enable_bandwidth_manager (#9441)
Signed-off-by: dcwbq <biqiang.wu@daocloud.io>

Signed-off-by: dcwbq <biqiang.wu@daocloud.io>
2022-10-28 03:08:31 -07:00

257 lines
10 KiB
YAML
Raw Permalink Blame History

This file contains ambiguous Unicode characters

This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.

---
cilium_min_version_required: "1.10"
# Log-level
cilium_debug: false
cilium_mtu: ""
cilium_enable_ipv4: true
cilium_enable_ipv6: false
# Cilium agent health port
cilium_agent_health_port: "{%- if cilium_version | regex_replace('v') is version('1.11.6', '>=') -%}9879 {%- else -%} 9876 {%- endif -%}"
# Identity allocation mode selects how identities are shared between cilium
# nodes by setting how they are stored. The options are "crd" or "kvstore".
# - "crd" stores identities in kubernetes as CRDs (custom resource definition).
# These can be queried with:
# `kubectl get ciliumid`
# - "kvstore" stores identities in an etcd kvstore.
# - In order to support External Workloads, "crd" is required
# - Ref: https://docs.cilium.io/en/stable/gettingstarted/external-workloads/#setting-up-support-for-external-workloads-beta
# - KVStore operations are only required when cilium-operator is running with any of the below options:
# - --synchronize-k8s-services
# - --synchronize-k8s-nodes
# - --identity-allocation-mode=kvstore
# - Ref: https://docs.cilium.io/en/stable/internals/cilium_operator/#kvstore-operations
cilium_identity_allocation_mode: kvstore
# Etcd SSL dirs
cilium_cert_dir: /etc/cilium/certs
kube_etcd_cacert_file: ca.pem
kube_etcd_cert_file: node-{{ inventory_hostname }}.pem
kube_etcd_key_file: node-{{ inventory_hostname }}-key.pem
# Limits for apps
cilium_memory_limit: 500M
cilium_cpu_limit: 500m
cilium_memory_requests: 64M
cilium_cpu_requests: 100m
# Overlay Network Mode
cilium_tunnel_mode: vxlan
# Optional features
cilium_enable_prometheus: false
# Enable if you want to make use of hostPort mappings
cilium_enable_portmap: false
# Monitor aggregation level (none/low/medium/maximum)
cilium_monitor_aggregation: medium
# Kube Proxy Replacement mode (strict/probe/partial)
cilium_kube_proxy_replacement: probe
# If upgrading from Cilium < 1.5, you may want to override some of these options
# to prevent service disruptions. See also:
# http://docs.cilium.io/en/stable/install/upgrade/#changes-that-may-require-action
cilium_preallocate_bpf_maps: false
# `cilium_tofqdns_enable_poller` is deprecated in 1.8, removed in 1.9
cilium_tofqdns_enable_poller: false
# `cilium_enable_legacy_services` is deprecated in 1.6, removed in 1.9
cilium_enable_legacy_services: false
# Deploy cilium even if kube_network_plugin is not cilium.
# This enables to deploy cilium alongside another CNI to replace kube-proxy.
cilium_deploy_additionally: false
# Auto direct nodes routes can be used to advertise pods routes in your cluster
# without any tunelling (with `cilium_tunnel_mode` sets to `disabled`).
# This works only if you have a L2 connectivity between all your nodes.
# You wil also have to specify the variable `cilium_native_routing_cidr` to
# make this work. Please refer to the cilium documentation for more
# information about this kind of setups.
cilium_auto_direct_node_routes: false
# Allows to explicitly specify the IPv4 CIDR for native routing.
# When specified, Cilium assumes networking for this CIDR is preconfigured and
# hands traffic destined for that range to the Linux network stack without
# applying any SNAT.
# Generally speaking, specifying a native routing CIDR implies that Cilium can
# depend on the underlying networking stack to route packets to their
# destination. To offer a concrete example, if Cilium is configured to use
# direct routing and the Kubernetes CIDR is included in the native routing CIDR,
# the user must configure the routes to reach pods, either manually or by
# setting the auto-direct-node-routes flag.
cilium_native_routing_cidr: ""
# Allows to explicitly specify the IPv6 CIDR for native routing.
cilium_native_routing_cidr_ipv6: ""
# Enable transparent network encryption.
cilium_encryption_enabled: false
# Encryption method. Can be either ipsec or wireguard.
# Only effective when `cilium_encryption_enabled` is set to true.
cilium_encryption_type: "ipsec"
# Enable encryption for pure node to node traffic.
# This option is only effective when `cilium_encryption_type` is set to `ipsec`.
cilium_ipsec_node_encryption: false
# If your kernel or distribution does not support WireGuard, Cilium agent can be configured to fall back on the user-space implementation.
# When this flag is enabled and Cilium detects that the kernel has no native support for WireGuard,
# it will fallback on the wireguard-go user-space implementation of WireGuard.
# This option is only effective when `cilium_encryption_type` is set to `wireguard`.
cilium_wireguard_userspace_fallback: false
# Enable Bandwidth Manager
# Ciliums bandwidth manager supports the kubernetes.io/egress-bandwidth Pod annotation.
# Bandwidth enforcement currently does not work in combination with L7 Cilium Network Policies.
# In case they select the Pod at egress, then the bandwidth enforcement will be disabled for those Pods.
# Bandwidth Manager requires a v5.1.x or more recent Linux kernel.
cilium_enable_bandwidth_manager: false
# IP Masquerade Agent
# https://docs.cilium.io/en/stable/concepts/networking/masquerading/
# By default, all packets from a pod destined to an IP address outside of the cilium_native_routing_cidr range are masqueraded
cilium_ip_masq_agent_enable: false
### A packet sent from a pod to a destination which belongs to any CIDR from the nonMasqueradeCIDRs is not going to be masqueraded
cilium_non_masquerade_cidrs:
- 10.0.0.0/8
- 172.16.0.0/12
- 192.168.0.0/16
- 100.64.0.0/10
- 192.0.0.0/24
- 192.0.2.0/24
- 192.88.99.0/24
- 198.18.0.0/15
- 198.51.100.0/24
- 203.0.113.0/24
- 240.0.0.0/4
### Indicates whether to masquerade traffic to the link local prefix.
### If the masqLinkLocal is not set or set to false, then 169.254.0.0/16 is appended to the non-masquerade CIDRs list.
cilium_masq_link_local: false
### A time interval at which the agent attempts to reload config from disk
cilium_ip_masq_resync_interval: 60s
# Hubble
### Enable Hubble without install
cilium_enable_hubble: false
### Enable Hubble Metrics
cilium_enable_hubble_metrics: false
### if cilium_enable_hubble_metrics: true
cilium_hubble_metrics: {}
# - dns
# - drop
# - tcp
# - flow
# - icmp
# - http
### Enable Hubble install
cilium_hubble_install: false
### Enable auto generate certs if cilium_hubble_install: true
cilium_hubble_tls_generate: false
# IP address management mode for v1.9+.
# https://docs.cilium.io/en/v1.9/concepts/networking/ipam/
cilium_ipam_mode: kubernetes
# Extra arguments for the Cilium agent
cilium_agent_custom_args: []
# For adding and mounting extra volumes to the cilium agent
cilium_agent_extra_volumes: []
cilium_agent_extra_volume_mounts: []
cilium_agent_extra_env_vars: []
cilium_operator_replicas: 2
# The address at which the cillium operator bind health check api
cilium_operator_api_serve_addr: "127.0.0.1:9234"
## A dictionary of extra config variables to add to cilium-config, formatted like:
## cilium_config_extra_vars:
## var1: "value1"
## var2: "value2"
cilium_config_extra_vars: {}
# For adding and mounting extra volumes to the cilium operator
cilium_operator_extra_volumes: []
cilium_operator_extra_volume_mounts: []
# Extra arguments for the Cilium Operator
cilium_operator_custom_args: []
# Name of the cluster. Only relevant when building a mesh of clusters.
cilium_cluster_name: default
# Make Cilium take ownership over the `/etc/cni/net.d` directory on the node, renaming all non-Cilium CNI configurations to `*.cilium_bak`.
# This ensures no Pods can be scheduled using other CNI plugins during Cilium agent downtime.
# Available for Cilium v1.10 and up.
cilium_cni_exclusive: true
# Configure the log file for CNI logging with retention policy of 7 days.
# Disable CNI file logging by setting this field to empty explicitly.
# Available for Cilium v1.12 and up.
cilium_cni_log_file: "/var/run/cilium/cilium-cni.log"
# -- Configure cgroup related configuration
# -- Enable auto mount of cgroup2 filesystem.
# When `cilium_cgroup_auto_mount` is enabled, cgroup2 filesystem is mounted at
# `cilium_cgroup_host_root` path on the underlying host and inside the cilium agent pod.
# If users disable `cilium_cgroup_auto_mount`, it's expected that users have mounted
# cgroup2 filesystem at the specified `cilium_cgroup_auto_mount` volume, and then the
# volume will be mounted inside the cilium agent pod at the same path.
# Available for Cilium v1.11 and up
cilium_cgroup_auto_mount: true
# -- Configure cgroup root where cgroup2 filesystem is mounted on the host
cilium_cgroup_host_root: "/run/cilium/cgroupv2"
# Specifies the ratio (0.0-1.0) of total system memory to use for dynamic
# sizing of the TCP CT, non-TCP CT, NAT and policy BPF maps.
cilium_bpf_map_dynamic_size_ratio: "0.0025"
# -- Enables masquerading of IPv4 traffic leaving the node from endpoints.
# Available for Cilium v1.10 and up
cilium_enable_ipv4_masquerade: true
# -- Enables masquerading of IPv6 traffic leaving the node from endpoints.
# Available for Cilium v1.10 and up
cilium_enable_ipv6_masquerade: true
# -- Enable native IP masquerade support in eBPF
cilium_enable_bpf_masquerade: false
# -- Configure whether direct routing mode should route traffic via
# host stack (true) or directly and more efficiently out of BPF (false) if
# the kernel supports it. The latter has the implication that it will also
# bypass netfilter in the host namespace.
cilium_enable_host_legacy_routing: true
# -- Enable use of the remote node identity.
# ref: https://docs.cilium.io/en/v1.7/install/upgrade/#configmap-remote-node-identity
cilium_enable_remote_node_identity: true
# -- Enable the use of well-known identities.
cilium_enable_well_known_identities: false
# The monitor aggregation flags determine which TCP flags which, upon the
# first observation, cause monitor notifications to be generated.
#
# Only effective when monitor aggregation is set to "medium" or higher.
cilium_monitor_aggregation_flags: "all"
cilium_enable_bpf_clock_probe: true
# -- Whether to enable CNP status updates.
cilium_disable_cnp_status_updates: true
# Configure how long to wait for the Cilium DaemonSet to be ready again
cilium_rolling_restart_wait_retries_count: 30
cilium_rolling_restart_wait_retries_delay_seconds: 10
# Cilium changed the default metrics exporter ports in 1.12
cilium_agent_scrape_port: "{{ cilium_version | regex_replace('v') is version('1.12', '>=') | ternary('9962', '9090') }}"
cilium_operator_scrape_port: "{{ cilium_version | regex_replace('v') is version('1.12', '>=') | ternary('9963', '6942') }}"
cilium_hubble_scrape_port: "{{ cilium_version | regex_replace('v') is version('1.12', '>=') | ternary('9965', '9091') }}"